Problem Summary


Negative Quantity under storage type 910

Admin Info


Purpose
Negative Quantiity under storage typw 910
Requested by
Poter
Issue Date
10-18-2016
Resolved by
Adithya
Resolved Date
10-18-2016
Document Status
Complete

Detailed Problem Description

(Include Screen Shots if required )

When looked at the report looks like there is Negative quantity under storage location 910.

Solution Analysis and Recommendations

(Include Screen Shots if required)


Understand that goods issue to subcontractor is not completed in the WM system, to resolve this issue kindly create the transfer order using open transfer requirement 9832 using transaction LT04 and confirm the TO.

Resolution


Create Transfer Orders and confirm the same.